First, YBX3 series high efficiency flameproof three-phase asynchronous motor
Product details page


The explosion-proof mark is ExdⅠ, ExdⅡAT4, ExdⅡBT4, and the maximum surface temperature of class Ⅰ does not exceed 150 ° C (when coal dust may accumulate on the motor surface), and does not exceed 450 ° C (when the motor surface does not accumulate or measures can be taken to prevent coal dust accumulation); The maximum surface temperature of class II should not exceed: T1(450 ° C), T2(300 ° C), T3(200 ° C), T4(135 ° C); The junction box can be made of three or six wire terminals respectively, which is suitable for two structures of rubber sheath cable (or plastic cable) and steel pipe wiring.

Application field:

Coal mine (non-mining face)(Ex dⅠ) and factory (Ex dⅡAT4, dⅡBT4) containing methane and other gases or coal dust places that contain inflammable gases or explosive mixtures formed by steam and air in groups A and B of Class II.



Two, YFB series dust explosion-proof three-phase asynchronous motor
Product details page
Application field:

YFB series dust explosion-proof three-phase asynchronous motor is a derivative of YB3 series flameproof motor, widely used in dust environment, such as grain processing machinery and crushing machinery.



Three, YB3 series flameproof three-phase asynchronous motor


Product details page

Application field:

YB3 series flameproof three-phase asynchronous motor is the replacement of YB2 series motor, suitable for coal mine fixed equipment and factory II A class, II B class, temperature groups are T1~T4 group of flammable gas or steam and air formed explosive mixture.


Ac motor; YBBP-225M-4 45kW 380V/50Hz V15
Gas engine accessories (charger belt); 350-7106; CAT G3520C
Gas engine accessories (charger belt); 350-7106; CAT G3520C
Drill motor moving plug-in fixed block
Outdoor motor; TTA250; YDK600-8AA9; 380/415V
Outdoor motor; TTA250; YDK600-8AA9; 380/415V
Outdoor motor; TTA250; YDK600-8AA9; 380/415V; The 3000-11
Outdoor motor; TTA250; YDK300-4; 380/451V
Electric machine; YDK3000-4; 3KW; 380V
Auxiliary generator copper bar mounting plate; E - ZJ290JV. 02.01
Pump/agitator motor junction box; E - JQZ01.02
Pump/agitator motor junction box; E - JQZ02.02
Pump/agitator motor junction box; E - JQZ03.02
Pump/agitator motor junction box; E - JQZ04.02
Battery charger; CDY889
Battery charger; CDY889
Battery charger; CDY889
Battery charger; CDY889
Battery charger; CDY889
Electric machine; M2JA-100L4B-IMB35; 3KW; 460v; 60hz
Electric machine; M2QA90L2A; 2.53 KW. 460V; 60Hz
Electric machine; M2QA90L2A; 2.53 KW. 460V; 60Hz
Generator control panel; EGCP-2; 8406-121.
Generator control panel; EGCP-2; 8406-121.
Electric machine; M2JA225M4A-W; V15; 45KW
Electric machine; M2JA225M4A-W; V15; 45KW
Electric machine; M2JA90S4A; 1.27 kw
Electric machine; M2JA90S4A; 1.27 kw
Auxiliary generator copper bar mounting plate; E - ZJ415JV. 05.01
Generator synchronous closing lamp button; 9001KXRB1A
Electric machine; 1LG6313-8PM80-Z
Electric machine; 1LG6313-8PM80-Z
Auxiliary generator copper bar mounting plate; E - ZJ412JC. 07.01
Auxiliary generator copper bar mounting plate; E - ZJ412JC. 07.01
Generator copper bar mounting plate; E - ZJ412JC. 08.01
Generator copper bar mounting plate; E - ZJ412JC. 08.01
Auxiliary generator copper bar mounting plate; E - ZJT040JV1. 07.01
Auxiliary generator copper bar mounting plate; E - ZJT040JV1. 07.01
Generator copper bar mounting plate; E - ZJT040JV1. 08.01
Generator copper bar mounting plate; E - ZJT040JV1. 08.01
Direct drive motor transfer box; RD023.001
Motor step-down starting cabinet
Motor direct start cabinet
Electric machine; Dedicated to Ross Hill system; 600V; 2.0 HP; 50Hz
AGC4; Automatic generator set controller; D1-E1-G5-H2-N-J1; Tape plate
10kV generator set switch cabinet; KYN28A-12
Generator control panel; EASYGEN-3200-5; 8440-2050.
Generator control panel; EASYGEN-3200-5; 8440-2050.
Generator control panel; EASYGEN-3200-5; 8440-2050.
Generator control panel; EASYGEN-3200-5; 8440-2050.
Power generation cabinet cabinet; 1000mm×600mm×1500mm
Battery charger; CD24V60A17CD
Battery charger; CD24V60A17CD
Generator skylight outlet plate; E - ZJT048JC. 06.01
Generator accessories (space heaters); 139-0387; 1000W; 120V
Generator accessories (space heaters); 139-0387; 1000W; 120V
Generator idle switch; Run-Idle-Off; E30AG
The main board of the air conditioner contains a motor; BYTF-45FRG
Generator skylight outlet plate; E - ZJ486JV1. 15.01
Automatic generator set controller; AGC4; D1-E1-G5-H2-M15-N-I1-J1; with
Generator copper bar mounting plate; E - ZJ492JV. 07.01
Electric machine; NEX182T-2; B3; 3HP; 600V; 60Hz
Electric machine; NEX284TC-6; B35; 15HP; 600V; 60Hz
Electric machine; NEX286TSC-2; B35; 30HP; 600V; 60Hz
ABB motor; M2JA160L4A; B3; 17.3 kW. 460V; 60Hz
Nanyang Electric Machine; YBKD165; 165W; 220V/230V; 50Hz
Axial flow fan; YTDZ-4-480; 2.53 kW. 480V; 60HZ
Axial flow fan; TYPE-FJ02A
Axial flow fan; TYPE-FJ02A
Axial flow fan; YTDZ-4-380; 1.53 kW. 380V; 50Hz
Axial flow fan; YTDZ-4-380; 1.53 kW. 380V; 50HZ
Axial flow fan; YTDZ-4-380; 380V;
Axial flow fan; YTDZ-4-380; 380V;
Axial flow fan; YTDZ-4-380; 380V;
Brake resistance; 25kW×1; 4 Ω x 1; ACS800
Brake resistance; 25kW×1; 4 Ω x 1; ACS800
Brake resistance; 25kW×1; 4 Ω x 1; ACS800
Brake resistance; 25kW×1; 4 Ω x 1; ACS800
Brake resistance; 25kW×1; 4 Ω x 1; ACS800
Brake resistance; 25 kw * 1 1/4 Ω; ACS800
Brake resistance; 100kW×1; 2.3 Ω x 1
Brake resistance; 100 kw * 1/2.3 Ω * 1
Brake resistance; 100kW×6+25kW×1; 2.3 Ω * 6 + 4 Ω * 1;
Brake resistance; 100kW×2; 2.3 Ω x 2
Brake resistance; 100kW×2; 2.3 Ω x 2
Brake resistance; 100kW×2; 2.3 Ω x 2
Brake resistance; 100 kw * 2/2.3 Ω * 2
Brake resistance; 100kW×8+25kW×1; 2.3 Ω * 8 + 4 Ω * 1
Brake resistance; 100kW×8+25kW×1; 2.3 Ω * 8 + 4 Ω * 1
Brake resistance; 100kW×8+25kW×1; 2.3 Ω * 8 + 4 Ω * 1
Temperature transmitter; 509-75-90N
Temperature sensor; PT100; WZP-426
Temperature sensor; PT100; WZP-426
Temperature sensor; PT100; WZP-426;
Temperature sensor; PT100; WZP-426;
Brake resistance; 200kW×1; 2.3 Ω x 1
Brake resistance; 200kW×1; 2.3 Ω x 1
Brake resistance; 200kW×1; 2.3 Ω x 1
Brake resistance; 200kW×1; 2.3 Ω x 1
Brake resistance; 200kW×1; 2.3 Ω x 1
Brake resistance; 200 kw * 1/2.3 Ω * 1;
Temperature sensor; PT100; WZP-421
Temperature sensor; PT100; WZP-421
Temperature sensor; PT100; WZP-421
Temperature sensor; PT100; WZP-421
Temperature sensor; PT100; WZP-421
Brake resistance; 100kW×6+25kW×1; 2.3 Ω * 6 + 4 Ω * 1
Brake resistance; 100kW×6+25kW×1; 2.3 Ω * 6 + 4 Ω * 1
Brake resistance; 100kW×6+25kW×1; 2.3 Ω * 6 + 4 Ω * 1
Brake resistance; 100kW×6+25kW×1; 2.3 Ω * 6 + 4 Ω * 1
Brake resistance; 100kW×6+25kW×1; 2.3 Ω * 6 + 4 Ω * 1
Brake resistance; 100 kw * 6 + 25 kw * 6/2.3 Ω 1/4 Ω x 1
Brake resistance; 100 kw * 6 + 25 kw * 6/2.3 Ω 1/4 Ω x 1
Brake resistance; 100 kw * 6 + 25 kw * 6/2.3 Ω 1/4 Ω x 1
Brake resistance; 100kW×4+25kW×1; 2.3 Ω * 4 + 4 Ω * 1
Brake resistance; 100kW×4+25kW×1; 2.3 Ω * 4 + 4 Ω * 1
Brake resistance; 100kW×4+25kW×1; 2.3 Ω * 4 + 4 Ω * 1
Brake resistance; 100 kw * 4 + 25 kw * 4/2.3 Ω 1/4 Ω x 1
Brake resistance; 100 kw * 4 + 25 kw * 4/2.3 Ω 1/4 Ω x 1
Brake resistance; 100 kw * 4 + 25 kw * 4/2.3 Ω 1/4 Ω x 1
Electric machine; M2QA90L2A; 2.53 KW. 460V; 60Hz
Brake resistance; 25kW×1+45kW×1; 4 Ω * 1 + 0.48 Ω * 1
Brake resistance; 25 kw * 1 + 45 kw * 1 + 0.48 Ω x 1 1/4 Ω
Brake resistance; 15kW×3; 0.16 Ω x3
Brake resistance; 200kW×6+25kW×1; 0.767 Ω * 6 + 4 Ω * 1; S120
Brake resistance; 200 kw * 6 + 25 kw * 1/0.767 Ω * 6 + 4 Ω * 1; S120
Brake resistance; 240 kw * 2/1.8 Ω * 2
Brake resistance; 45 kw * 1/0.48 Ω * 1
Brake resistance unit; DZ48C-200-000ß
Brake resistance unit; DZ48C-200-000ß
Brake resistance; 350 kw * 2/1.4 Ω * 2
Brake resistance; 460 kw * 1 + 25 kw * 1/1 Ω Ω * 1 * 1 + 4
Salt spray filter; YTDZ-YW1
Brake resistance; 50kW×1+25kW×1; 2.3 Ω * 1 + 4 Ω * 1; YTDZH7; 66
Brake resistance; 50kW×1+25kW×1; 2.3 Ω * 1 + 4 Ω * 1; YTDZH7; 66
Brake resistance; 45 kw * 1 1/3 Ω
Brake resistance; 25kW×1; 4 Ω x 1